4. Advanced Operation
PROGRAMMABLE AC POWER SOURCE
134
6.
To save the set content into memory, move the cursor to [Save], then press the ENTER key.
7.
Move the cursor to [Close], then press the ENTER key. The clipped sine wave setting window
closes.
--------
Notes
----------------------------------------------------------------------------------------------------------------
Executing [Save] saves all the settings from CLP1 to CLP3 into the internal memory.
Settings not saved in the internal memory are lost when the power is turned off.
The clip ratio setting value and the crest factor setting value are held independently of each
other. The setting value switch as the Type is changed. Each setting value is saved per
waveform when the settings are saved into the internal memory.
The clipped sine wave memory cannot be cleared (to the factory defaults). Manually set to the
factory default settings of Clip = 100%, CF = 1.41, Type = Clip, then save them.
---------------------------------------------------------------------------------------------------------------------------------
4.7 Outputting
Arbitrary
Waveform
4.7.1 Basics
Arbitrary waveform can be selected as the output waveform with this product. Using the control
software Wave Designer in the attached CD-ROM, you can create, edit, and transfer arbitrary
waveforms to this product's internal memory through the USB interface. Alternatively, you can
create and save the arbitrary waveform data in a USB memory and then transfer it to the internal
memory of this product through this product's panel operation. Up to 16 types of arbitrary
waveforms can be saved in the internal memory. For Wave Designer, see the instruction manual of
the control software.
--------
Notes
----------------------------------------------------------------------------------------------------------------
Arbitrary waveform cannot be created and edited through the panel operation of this product.
---------------------------------------------------------------------------------------------------------------------------------
Содержание DP015S
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Страница 4: ......
Страница 18: ......
Страница 19: ...DP Series 1 1 Outline 1 1 Overview 2 1 2 Series Line up and Polyphase System Configuration 2 1 3 Features 4 ...
Страница 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Страница 215: ...DP Series 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202 ...
Страница 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Страница 225: ...DP Series 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 214 ...
Страница 237: ...7 8 Replacement Air Filter DP Series 219 フロントグリル フロントグリル Front grill 1 Front grill 2 Figure 7 2 Front Grills ...
Страница 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Страница 239: ...DP Series 221 8 Troubleshooting 8 1 Error Messages and Error Handling 222 8 2 When a Failure is Suspected 229 ...
Страница 298: ......
Страница 300: ......
Страница 302: ......
Страница 303: ......
Страница 304: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN ...