10. Specifications
PROGRAMMABLE AC POWER SOURCE
244
10.4 Signal
Source
Single-phase
model,
Multi-phase
model
Polyphase model, Polyphase system
Signal source
INT, VCA, SYNC,
EXT, ADD
INT, VCA, SYNC
Description
INT
Uses the internal signal source.
Sets the output voltage, output waveform, frequency, output on phase, and
output off phase by using the panel or the external interface such as USB.
Fixed to INT in the Sequence and Simulation.
VCA
Uses the internal signal source.
Controls the output voltage setting of the internal signal source with the DC
signal which is input to the external input terminal. The output voltage setting
cannot be set from external interfaces such as the panel or USB. All conditions
except for output voltage setting is same as INT.
In the polyphase model, polyphase system, and polyphase output of the
Multi-phase model, the setting is common to all the phases.
Cannot be selected in the AC+DC mode.
SYNC
Uses the internal signal source.
Synchronizes the frequency of the internal signal source with the signal (EXT)
from the external synchronization signal input terminal (also used as the
external input terminal) or the power supply input frequency (LINE) of the
product. The frequency setting cannot be set from external interfaces such as
the panel or USB. All conditions except for output frequency setting is same as
INT.
Cannot be selected in the DC mode.
EXT
(Optional)
Uses the external signal source.
Amplifies the signal from the external input terminal by the specified gain
(variable), and outputs it.
Cannot be selected for the polyphase model, the polyphase system, and
polyphase output of the Multi-phase model.
Cannot be selected in the DC mode.
ADD
(Optional)
Uses both the internal and external signal sources.
Amplifies the signal from the external input terminal by the specified gain like
EXT, and adds the internal signal source component to it.
Cannot be selected for the polyphase model, the polyphase system, and
polyphase output of the Multi-phase model.
Cannot be selected in the DC mode.
Содержание DP015S
Страница 1: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL NF Corporation ...
Страница 2: ......
Страница 3: ...PROGRAMMABLE AC POWER SOURCE DP Series INSTRUCTION MANUAL DA00027113 001 ...
Страница 4: ......
Страница 18: ......
Страница 19: ...DP Series 1 1 Outline 1 1 Overview 2 1 2 Series Line up and Polyphase System Configuration 2 1 3 Features 4 ...
Страница 24: ...1 Outline PROGRAMMABLE AC POWER SOURCE 6 ...
Страница 215: ...DP Series 197 5 Description of Screen and Menu 5 1 Screen Configuration 198 5 2 Menu Composition 202 ...
Страница 224: ...5 Description of Screen and Menu PROGRAMMABLE AC POWER SOURCE 206 ...
Страница 225: ...DP Series 207 6 Remote Control 6 1 Communication Interface 208 6 2 Remote Local State Switching 214 ...
Страница 237: ...7 8 Replacement Air Filter DP Series 219 フロントグリル フロントグリル Front grill 1 Front grill 2 Figure 7 2 Front Grills ...
Страница 238: ...7 Options PROGRAMMABLE AC POWER SOURCE 220 ...
Страница 239: ...DP Series 221 8 Troubleshooting 8 1 Error Messages and Error Handling 222 8 2 When a Failure is Suspected 229 ...
Страница 298: ......
Страница 300: ......
Страница 302: ......
Страница 303: ......
Страница 304: ...http www nfcorp co jp NF Corporation 6 3 20 Tsunashima Higashi Kohoku ku Yokohama 223 8508 JAPAN ...