QV
set average motor voltage
IMM
PGM
MIP
USAGE
♦
♦
SYNTAX
xx
QV
nn or xx
QV
?
PARAMETERS
Description
xx
[ int ] -
axis number
nn
[float] -
motor voltage
Range
xx
-
1
to
MAX AXES
nn
-
0
to maximum driver rating (see Specifications section)
or
?
to read present setting
Units
xx
-
none
nn
-
none
Defaults
xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error 9, AXIS NUMBER OUT OF RANGE
nn
missing:
error 38, COMMAND PARAMETER MISSING
out of range:
error xx2, PARAMETER OUT OF RANGE
DESCRIPTION
This command is used to set the average motor voltage output for a Newport
Unidrive compatible programmable driver axis. This command must to be
followed by the
QD
update driver command to take affect.
RETURNS
If the “?” sign takes the place of
nn
value, this command reports the current
setting
REL. COMMANDS
QD
-
update driver
QI
-
set maximum motor current
QG
-
set gear constant
QS -
set microstep factor
QT
-
set tachometer gain
EXAMPLE
2QV?
|
read average motor voltage setting of axis # 2
48.0
|
controller returns a
value of 48Volts for axis #2
2QV 12
|
set average motor voltage to 12 Volts for axis #2
2QD
|
update programmable driver with latest settings for axis #2
SM
|
save all controller settings to non-volatile memory
Section 3 – Remote Mode
3-121
Содержание ESP300 Series
Страница 1: ...ESP300 Motion Controller Driver User s Manual...
Страница 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Страница 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Страница 30: ......
Страница 230: ...4 16 Section 4 Advanced Capabilities...
Страница 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Страница 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...