BG
assign DIO bits to execute stored programs
IMM
PGM
MIP
USAGE
♦
♦
SYNTAX
xxBGnn
or
xxBG?
PARAMETERS
Description
xx
[ int ]
-
bit number used to trigger stored program execution
nn
[ char ]
-
name of stored program to be executed
Range
xx
-
0
to
15
nn
- None
or
?
to read current setting
Units
None
Defaults xx
missing:
error 7, PARAMETER OUT OF RANGE
out of range:
error 7, PARAMETER OUT OF RANGE
DESCRIPTION
This command is used to assign DIO bits for initiating the execution of a desired
stored program. Execution of the stored program begins when the specified DIO
bit changes its state from HIGH to LOW logic level.
Note:
Each DIO bit has a pulled-up resistor to +5V. Therefore, all bits will be at HIGH
logic level if not connected to external circuit and configured as input.
RETURNS
If the "?" sign takes the place of
nn
value, this command reports the current
setting.
REL. COMMANDS
BO
-
Set DIO port A, B, direction
EP
-
Enter program mode
EX
-
Execute stored program
AP
-
Abort stored program execution
EXAMPLE
BO
0H
|
Set DIO ports A and B to input
0 BG 1
|
Start execution of a stored program 1 when DIO bit #0 changes
state from HIGH to LOW
Section 3 – Remote Mode
3-31
Содержание ESP300 Series
Страница 1: ...ESP300 Motion Controller Driver User s Manual...
Страница 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Страница 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Страница 30: ......
Страница 230: ...4 16 Section 4 Advanced Capabilities...
Страница 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Страница 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...