ID
read stage model and serial number
IMM
PGM
MIP
USAGE
♦
♦
SYNTAX
ID ? or IDxx
PARAMETERS
Description
xx
[ int ] -
axis number
Range
xx
-
1
to
MAX AXES
Units
xx
-
none
Defaults
xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error 9, AXIS NUMBER OUT OF RANGE
timeout:
error 2, RS-232 COMMUNICATION TIME-OUT
DESCRIPTION
This command is used to read and write (up to 16 character custom ID) Newport
ESP compatible positioner (stage) model and serial number.
Note:
An important information needed when asking for help with the motion control
system or when reporting a problem is the stage model and serial number. Use
this command to determine the positioner model and serial number.
RETURNS
xx,yy
where:
xx
= model number
yy
= serial number
REL. COMMANDS
none
EXAMPLE
1
ID
?
|
read axis-1 positioner model and serial number
TS50DC.5, SN1263
|
controller returns model and serial number