KS
set saturation level of integral factor
IMM
PGM
MIP
USAGE
♦
♦
♦
SYNTAX
xx
KS
nn or xx
KS
?
PARAMETERS
Units
xx
-
none
out of range:
error 9, AXIS NUMBER OUT OF RANGE
nn
missing:
error 38, COMMAND PARAMETER MISSING
The command can be sent at any time but it has no effect until the UF (update
UF -
update filter
•
Description
xx
[ int ] -
axis number
nn
[float] -
saturation level of integrator KS
Range
xx
-
1
to
MAX AXES
nn
-
0
to
2e9,
or
?
to read current setting
nn
-
none
Defaults
xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error xx2, PARAMETER OUT OF RANGE
DESCRIPTION
This command sets the saturation level of the integral factor of the PID closed
loop and is useful for preventing integral wind-up. It is active for any DC servo
based motion device that has been selected to operate in closed loop.
filter)
is
received.
.
See the "
Servo Tuning
" chapter on how to adjust the PID filter parameters.
RETURNS
If the “?” sign takes the place of
nn
value, this command reports the current
setting
REL. COMMANDS
KI
-
set integral gain factor
KP -
set proportional gain factor
KD -
set derivative gain factor
EXAMPLE
3KS0.01 |
set saturation level for axis # 3 to 0.01
•
•
3UF
|
update PID filter; only now the
KS
command takes effect
3-94
Section
3
–
Remote
Mode
Содержание ESP300 Series
Страница 1: ...ESP300 Motion Controller Driver User s Manual...
Страница 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Страница 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Страница 30: ......
Страница 230: ...4 16 Section 4 Advanced Capabilities...
Страница 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Страница 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...