SU
set encoder resolution
IMM PGM
MIP
USAGE
♦
♦
SYNTAX
xx
SU
nn or xx
SU
?
PARAMETERS
Description
xx
[ int ] -
axis number
nn
[float] -
encoder resolution
Range
xx
-
1
to
MAX AXES
nn
-
2e-9
to
2e+9
in user defined units
or
?
to read present setting
Units
xx
-
none
nn
-
none
Defaults
xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error 9, AXIS NUMBER OUT OF RANGE
nn
missing:
error 38, COMMAND PARAMETER MISSING
out of range:
error xx2, PARAMETER OUT OF RANGE
DESCRIPTION
This command is used to set the encoder resolution for axis
xx
.
Note:
The encoder resolution can only be changed when encoder feedback is enabled.
See ZB command.
RETURNS
If “?” sign takes the place of
nn
value, this command reports the current setting
REL. COMMANDS
FR
-
set full-step resolution
SU
-
set encoder resolution
QD
-
update driver
ZB
-
set
feedback
configuration
EXAMPLE
2SU?
|
read encoder resolution setting of axis # 2
0.0001
|
controller returns a
value of 0.0001 units for axis #2
2SU0.0005 |
set encoder resolution to 0.0005 units for axis #2
2QD
|
update programmable driver with latest settings for axis #2
SM
|
save all controller settings to non-volatile memory
Section 3 – Remote Mode
3-137
Содержание ESP300 Series
Страница 1: ...ESP300 Motion Controller Driver User s Manual...
Страница 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Страница 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Страница 30: ......
Страница 230: ...4 16 Section 4 Advanced Capabilities...
Страница 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Страница 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...