Appendix G – Programming Non-ESP
Compatible Stages
Newport positioners, or stages, with integrated configuration memory
devices are said to be "ESP Compatible". It is not necessary to
manually enter individual stage parameters (E.G., motor current,
maximum velocity, etc.) with an ESP compatible stage. All necessary
configuration settings will be automatically loaded after system reset
with ESP compatible positioners.
When a positioner is said to be ESP incompatible, all that really
means is that it does not have the integrated memory device that
allows for automatic configuration. Therefore, it will have to be
configured manually – as is customary with all non-ESP controllers.
There are two (2) basic levels of positioner configuration. The first
level assumes that the stage is Newport controller compatible. That is
to say that hardware travel limits, encoder feedback counting, etc…
are designed to operate with Newport controllers. In this case only a
certain amount of commands are necessary to setup the axis before
moving the stage. The second level is when a stage is not a standard
Newport stage and various compatibility issues need to be addressed.
This scenario requires additional command configurations.
The following are examples of how to configure an ESP controller
axis for a standard Newport stage that is not equipped with the "ESP
Compatible" memory device (i.e., level 1):
1qm1
//set motor type to DC servo
1su0.005
//set resolution to 0.005 degrees
1au40
//set maximum acceleration to 40 deg/sec
Example #1: DC Servo on axis 1
1qi0.15
//set motor maximum current to 0.15 amps
1qv30
//set motor voltage to 30 volts
1sn7
//set user units to degrees
1vu15
//set maximum velocity to 15 deg/sec
1va7
//set working velocity to 7 deg/sec
1oh7
//set homing speed to 7 deg/sec
1jh7
//set jog high speed to 7 deg/sec
1jw1
//set jog low speed to 1 deg/sec
2
Appendix G – Programming Non-ESP Compatible Stages
G-1
Содержание ESP300 Series
Страница 1: ...ESP300 Motion Controller Driver User s Manual...
Страница 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Страница 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Страница 30: ......
Страница 230: ...4 16 Section 4 Advanced Capabilities...
Страница 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Страница 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...