FP
set position display resolution
IMM PGM MIP
USAGE
♦
♦
♦
SYNTAX
xx
FP
nn or xx
FP
?
PARAMETERS
Description
xx
[ int ]
-
axis number
nn
[ int ]
-
display resolution
Range
xx
-
1
to
MAX AXES
nn
-
0
to
7
or
?
to read present setting
Units
xx
-
none
nn
-
none
Defaults xx
missing:
error 37, AXIS NUMBER MISSING
out of range:
error 9, AXIS NUMBER OUT OF RANGE
nn
missing:
error 38, COMMAND PARAMETER MISSING
out of range:
error xx2, PARAMETER OUT OF RANGE
DESCRIPTION
This command is used to set the display resolution of position information. For
instance, if
nn = 4
, the display will show values as low as 0.0001 units. If
nn =
7
, the display will show values in exponential form. If the user units (refer SN
command) are in encoder counts or stepper increments, the position information
is displayed in integer form, independent of the value set by this command.
RETURNS
If “?” sign takes the place of
nn
value, this command reports current setting.
REL. COMMANDS
None
EXAMPLE
1FP?
|
read position display resolution for axis #1
4
|
controller returns a
value of 4
1TP
|
read actual position of axis #1
5.0001
|
controller returns position value
1FP2
|
set position display resolution for axis #1 to 2
1TP
|
read actual position of axis #1
5.00
|
controller returns position value
1FP7
|
set position display resolution for axis #1 to 7
1TP
|
read actual position of axis #1
5.0
|
controller returns position value
3-60
Section
3
–
Remote
Mode
Содержание ESP300 Series
Страница 1: ...ESP300 Motion Controller Driver User s Manual...
Страница 4: ...ESP300 1999 EU Declaration of Conformity iv Preface...
Страница 29: ...This page is intentionally left blank Section 2 Modes of Operation 1 15...
Страница 30: ......
Страница 230: ...4 16 Section 4 Advanced Capabilities...
Страница 274: ...This page is intentionally left blank 6 6 Section 6 Servo Tuning...
Страница 290: ...This page is intentionally left blank B 6 Appendix B Trouble Shooting and Maintenance...