CHAPTER 18 IEBus CONTROLLER (V850/SC2)
User’s Manual U15109EJ3V0UD
513
If the control bit received from the master unit is not as shown in Table 18-3, the unit locked by the master unit
reject accepting the control bit, and does not output the acknowledge bit.
Table 18-3. Control Field for Locked Slave Unit
Bit 3
Note 1
Bit 2
Bit 1
Bit 0
Function
0
0
0
0
Reads slave status
0
1
0
0
Reads lock address (lower 8 bits)
0
0
0
1
Reads lock address (higher 4 bits)
Moreover, units for which lock is not set by the master unit reject acknowledgement and do not output an
acknowledge bit when the control data shown in Table 18-4 is acknowledged.
Table 18-4. Control Field for Unlocked Slave Unit
Bit 3
Bit 2
Bit 1
Bit 0
Function
0
1
0
0
Lock address read (lower 8 bits)
0
1
0
1
Lock address read (higher 4 bits)
If one unit occupies the bus as the master, the value set to the IEBus control register (CDR) is output.
Figure 18-4. Control Field
MSB
LSB
ACK
Parity
Control bit (4 bits)
Control field