CHAPTER 18 IEBus CONTROLLER (V850/SC2)
User’s Manual U15109EJ3V0UD
531
Figure 18-12. Interrupt Generation Timing (for (2) and (5))
INTIE2
Flag set by reception
of 0H, 4H, 5H, 6H
IEBus sequence
Flag reset by
CPU processing
Error generated by
detection of NACK
Control field
STATUSF flag
Internal NACK flag
Control bits (4 bits)
Parity bit (1 bit)
ACK bit (1 bit)
Terminated by communication error
Because in (4) and (5) the communication was from other than the unit that sent the lock request while the
IEBus was in the locked state, the start or communication complete interrupt (INTIE2) is not generated,
even if the IEBus unit is the communication target. The STATUSF flag (bit 4 of the ISR register) is set and
the status interrupt (INTIE2) generated, however, if a slave status or lock address request is
acknowledged. Note that even if the same control data is received while the IEBus is in the locked state,
the interrupt generation timing for INTIE2 differs depending on whether the master unit (3) or another unit
(4) is requesting the locked state.
Figure 18-13. Timing of INTIE2 Interrupt Generation in Locked State (for (4) and (5))
INTIE2
IEBus sequence
Status
interrupt
Start
Master address
(12 + P)
Broadcast
Slave address
(12 + P + A)
Control
(4 + P + A)
Telegraph length
Note
(8 + P + A)
Data
Note
(8 + P + A)
Note
For (5), there is no ACK return and therefore no transition to telegraph length and data.
Remark
P: Parity bit, A: ACK/NACK bit
Figure 18-14. Timing of INTIE2 Interrupt Generation in Locked State (for (3))
INTIE2
IEBus sequence
Status
interrupt
Start
Master address
(12 + P)
Broadcast
Slave address
(12 + P + A)
Control
(4 + P + A)
Telegraph length
(8 + P + A)
Communication
complete interrupt
Data
(8 + P + A)
Start
interrupt
Remark
P: Parity bit, A: ACK/NACK bit