![NEC V850/SC1 Скачать руководство пользователя страница 663](http://html.mh-extra.com/html/nec/v850-sc1/v850-sc1_user-manual_248178663.webp)
CHAPTER 19 FCAN CONTROLLER (V850/SC3)
User’s Manual U15109EJ3V0UD
661
Figure 19-35. Setting of CANn Definition Register (CnDEF)
set MOM = 1
clear MOM = 0
START
No
Yes
Yes
Yes
Yes
clear MOM = 1
set MOM = 0
Set to diagnostic
processing mode?
Normal operating mode
Normal operation mode
Transmit priority is
determined based
on message numbers
Diagnostic processing mode
Transmit priority is determined
based on identifiers
Single-shot mode:
Transmit only once.
Do not retransmit.
clear DGM = 1
set DGM = 0
No
set DGM = 1
clear DGM = 0
Store to buffer used for
diagnostic processing mode
Note
?
clear PBB = 1
set PBB = 0
No
set PBB = 1
clear PBB = 0
Determine transmit priority
based on identifiers?
set SSHT = 1
clear SSHT = 0
No
clear SSHT = 1
set SSHT = 0
Set single-shot
mode?
Note
Bits 5 to 3 (MT2 to MT0) in CAN message configuration register m (M_CONFm) are set as “111”
Remark
n = 1, 2
m = 00 to 31