CHAPTER 20 ELECTRICAL SPECIFICATIONS
696
User’s Manual U15109EJ3V0UD
(c) Clock synchronous (T
A
= –40 to +85°C, V
DD
= 4.0 to 5.5 V, PORTV
DD
= 4.0 to 5.5 V)
Parameter
Symbol
Conditions
MIN.
MAX.
Unit
Delay time from CLKOUT
↑
to address
<39>
t
DKA
0
25
ns
Delay time from CLKOUT
↑
to address float
<40>
t
FKA
–12
10
ns
Delay time from CLKOUT
↓
to ASTB
<41>
t
DKST
0
19
ns
Delay time from CLKOUT
↑
to DSTB
<42>
t
DKD
0
19
ns
Data input setup time (to CLKOUT
↑
)
<43>
t
SIDK
20
ns
Data input hold time (from CLKOUT
↑
)
<44>
t
HKID
5
ns
Delay time from CLKOUT
↑
to data output
<45>
t
DKOD
19
ns
WAIT setup time (to CLKOUT
↓
)
<46>
t
SWTK
20
ns
WAIT hold time (from CLKOUT
↓
)
<47>
t
HKWT
5
ns
HLDRQ setup time (to CLKOUT
↓
)
<48>
t
SHQK
20
ns
HLDRQ hold time (from CLKOUT
↓
)
<49>
t
HKHQ
5
ns
Delay time from CLKOUT
↑
to address
float (during bus hold)
<50>
t
DKF
19
ns
Delay time from CLKOUT
↑
to HLDAK
<51>
t
DKHA
19
ns
Remark
The
values in the above specifications are values for when clocks with a 1:1 duty ratio are input from
X1.
(d) Clock synchronous
(T
A
= –40 to +85°C, PORTV
DD
= 3.0 to 4.0 V,
µµµµ
PD703068Y, 703069Y, 703088Y, 703089Y: V
DD
= 3.5 to 5.5 V,
µµµµ
PD70F3089Y: V
DD
= 4.0 to 5.5 V)
Parameter
Symbol
Conditions
MIN.
MAX.
Unit
Delay time from CLKOUT
↑
to address
<39>
t
DKA
0
40
ns
Delay time from CLKOUT
↑
to address float
<40>
t
FKA
–16
10
ns
Delay time from CLKOUT
↓
to ASTB
<41>
t
DKST
0
30
ns
Delay time from CLKOUT
↑
to DSTB
<42>
t
DKD
0
30
ns
Data input setup time (to CLKOUT
↑
)
<43>
t
SIDK
20
ns
Data input hold time (from CLKOUT
↑
)
<44>
t
HKID
5
ns
Delay time from CLKOUT
↑
to data output
<45>
t
DKOD
40
ns
WAIT setup time (to CLKOUT
↓
)
<46>
t
SWTK
24
ns
WAIT hold time (from CLKOUT
↓
)
<47>
t
HKWT
5
ns
HLDRQ setup time (to CLKOUT
↓
)
<48>
t
SHQK
24
ns
HLDRQ hold time (from CLKOUT
↓
)
<49>
t
HKHQ
5
ns
Delay time from CLKOUT
↑
to address
float (during bus hold)
<50>
t
DKF
19
ns
Delay time from CLKOUT
↑
to HLDAK
<51>
t
DKHA
35
ns
Remark
The
values in the above specifications are values for when clocks with a 1:1 duty ratio are input from
X1.