![NEC V850/SC1 Скачать руководство пользователя страница 664](http://html.mh-extra.com/html/nec/v850-sc1/v850-sc1_user-manual_248178664.webp)
CHAPTER 19 FCAN CONTROLLER (V850/SC3)
User’s Manual U15109EJ3V0UD
662
Figure 19-36. Setting of CANn Control Register (CnCTRL)
START
Yes
clear TMR = 1
set TMR = 0
Store timer value at SOF?
Set time stamp for
receiving
Set overwrite for receive
message buffer
Set dominant level for
transmit pins
Set dominant level for
receive pins
Store timer value at EOF
Do not overwrite message in
DN flag (delete new message)
Set dominant level
to high level
Set dominant level
to high level
set OVM = 1
clear OVM = 0
Yes
clear OVM = 1
set OVM = 0
Store message
in DN flag?
set DLEVT = 1
clear DLEVT = 0
Yes
clear DLEVT = 1
set DLEVT = 0
Set dominant level
to low level?
set DLEVR = 1
clear DLEVR = 0
Yes
No
No
No
No
clear DLEVR = 1
set DLEVR = 0
Set dominant level
to low level?
set TMR = 1
clear TMR = 0
Remark
n = 1, 2