CHAPTER 8 TIMER/COUNTER FUNCTION
290
User’s Manual U15109EJ3V0UD
Figure 8-26. Timing of One-Shot Pulse Output Operation via External Trigger (with Rising Edge Specified)
&
' '
,
,%
,%
−
,
"
"
!
1'
'
−
%
Caution
16-bit timer register n starts operating as soon as TMCn2 and TMCn3 are set to values other
than 0, 0 (operation stop mode).
Remark
n = 0, 1, 7 to 12
N > M