CHAPTER 17 FLASH MEMORY (
µµµµ
PD70F3089Y)
User’s Manual U15109EJ3V0UD
502
(2) Malfunction of other device
When connecting a dedicated flash programmer (output or input) to a serial interface pin (input or output) that is
connected to another device (input), the signal output to the other device may cause the device to malfunction.
To avoid this, isolate the connection to the other device or set so that the input signal to the other device is
ignored.
Figure 17-8. Malfunction of Other Device
V850/SC1, V850/SC2,
V850/SC3
Pin
In the flash memory programming mode, if the
signal the V850/SC1, V850/SC2, and V850/SC3
outputs affects the other device, isolate the signal on
the other device side.
Other device
Input pin
Dedicated flash programmer connection pin
V850/SC1, V850/SC2,
V850/SC3
Pin
In the flash memory programming mode, if the
signal the dedicated flash programmer outputs
affects the other device, isolate the signal on the
other device side.
Other device
Input pin