216
CHAPTER 18 METER CONTROLLER/DRIVER
18.3 Meter Controller/Driver Control Registers
The meter controller/driver is controlled by the following three registers.
• Timer mode control register (MCNTC)
• Compare control register n (MCMPCn)
• Port mode control register (PMC)
Remark
n = 1 to 4
(1) Timer mode control register (MCNTC)
MCNTC is an 8-bit register that controls the operation of the free-running up counter (MCNT).
MCNTC is set with an 8-bit memory manipulation instruction.
RESET input clears MCNTC to 00H.
Figure 18-3 shows the MCNTC format.
Figure 18-3. Timer Mode Control Register (MCNTC) Format
Address: FF69H After Reset: 00H R/W
Symbol
7
6
5
4
3
2
1
0
MCNTC
0
0
PCS
PCE
0
0
0
0
PCS
Timer Counter Clock Selection
0
f
X
1
f
X
/2
PCE
Timer Operation Control
0
Operation stopped (timer value is cleared)
1
Operation enabled
Cautions 1. When rewriting MCNTC to other data, stop the timer operation (PCE = 0) beforehand.
2. Bits 0 to 3, 6, and 7 must be set to 0.