160
CHAPTER 13 A/D CONVERTER
13.5 A/D Converter Cautions
(1) Current consumption in standby mode
A/D converter stops operating in the standby mode. At this time, current consumption can be reduced by setting
bit 7 (ADCS1) of the A/D converter mode register (ADM1) to 0 to stop conversion.
Figure 13-9 shows how to reduce the current consumption in the standby mode.
Figure 13-9. Example of Method of Reducing Current Consumption in Standby Mode
AV
REF
AV
SS
P-ch
Series resistor string
ADCS1
(2) Input range of ANI0 to ANI4
The input voltages of ANI0 to ANI4 should be within the specification range. In particular, if a voltage higher
than AV
REF
or lower than AV
SS
is input (even if within the absolute maximum rating range), the conversion value
of that channel will be undefined and the conversion values of other channels may also be affected.
(3) Contending operations
<1>
Contention between A/D conversion result register (ADCR1) write and ADCR1 read by instruction
upon the end of conversion
ADCR1 read is given priority. After the read operation, the new conversion result is written to ADCR1.
<2>
Contention between ADCR1 write and A/D converter mode register (ADM1) write or analog input
channel specification register (ADS1) write upon the end of conversion
ADM1 or ADS1 write is given priority. ADCR1 write is not performed, nor is the conversion end interrupt
request signal (INTAD) generated.
Содержание mPD780973 Series
Страница 2: ...2 MEMO ...
Страница 66: ...66 MEMO ...
Страница 98: ...98 MEMO ...
Страница 138: ...138 MEMO ...
Страница 164: ...164 MEMO ...
Страница 182: ...182 MEMO ...
Страница 204: ...204 MEMO ...
Страница 244: ...244 MEMO ...
Страница 262: ...262 MEMO ...
Страница 278: ...278 MEMO ...
Страница 290: ...290 MEMO ...