253
CHAPTER 21 RESET FUNCTION
21.1 Reset Function
The following two operations are available to generate the reset signal.
(1) External reset input with RESET pin
(2) Internal reset by watchdog timer overrun time detection
External reset and internal reset have no functional differences. In both cases, program execution starts at the
address at 0000H and 0001H by RESET input.
When a low level is input to the RESET pin or the watchdog timer overflows, a reset is applied and each hardware
is set to the status shown in Table 21-1. Each pin has high impedance during reset input or during oscillation
stabilization time just after reset clear.
When a high level is input to the RESET pin, the reset is cleared and program execution starts after the lapse of
oscillation stabilization time (2
17
/f
X
). The reset applied by watchdog timer overflow is automatically cleared after a
reset and program execution starts after the lapse of oscillation stabilization time (2
17
/f
X
) (see Figures 21-2 to 21-
4).
Cautions 1. For an external reset, input a low level for 10
µ
s or more to the RESET pin.
2. During reset input, main system clock oscillation remains stopped but subsystem clock
oscillation continues.
3. When the STOP mode is cleared by reset, the STOP mode contents are held during reset input.
However, the port pin becomes high-impedance.
Figure 21-1. Reset Function Block Diagram
RESET
Count clock
Reset control circuit
Watchdog timer
Stop
Overflow
Reset signal
Interrupt function
Содержание mPD780973 Series
Страница 2: ...2 MEMO ...
Страница 66: ...66 MEMO ...
Страница 98: ...98 MEMO ...
Страница 138: ...138 MEMO ...
Страница 164: ...164 MEMO ...
Страница 182: ...182 MEMO ...
Страница 204: ...204 MEMO ...
Страница 244: ...244 MEMO ...
Страница 262: ...262 MEMO ...
Страница 278: ...278 MEMO ...
Страница 290: ...290 MEMO ...