103
CHAPTER 7 16-BIT TIMER 0 TM0
7.4 16-Bit Timer 0 Control Registers
The following three types of registers are used to control timer 0.
• 16-bit timer mode control register (TMC0)
• Capture pulse control register (CRC0)
• Prescaler mode register (PRM0)
(1) 16-bit timer mode control register (TMC0)
This register sets the 16-bit timer operating mode and controls the prescaler output signals.
TMC0 is set with a 1-bit or 8-bit memory manipulation instruction.
RESET input clears TMC0 value to 00H.
Figure 7-2. 16-Bit Timer Mode Control Register (TMC0) Format
Address: FF72H After Reset: 00H R/W
Symbol
7
6
5
4
3
2
1
0
TMC0
0
0
0
0
0
TMC02
0
TPOE
TMC02
Timer 0 Operating Mode Selection
0
Operation stop (TM0 cleared to 0)
1
Operation enabled
TPOE
Timer 0 Prescaler Output Control
0
Prescaler signal output disabled
1
Prescaler signal output enabled
Cautions 1. Before changing the operation mode, stop the timer operation (by setting 0 to TMC02).
2. Bit 1 and bits 3 to 7 must be set to 0.
Содержание mPD780973 Series
Страница 2: ...2 MEMO ...
Страница 66: ...66 MEMO ...
Страница 98: ...98 MEMO ...
Страница 138: ...138 MEMO ...
Страница 164: ...164 MEMO ...
Страница 182: ...182 MEMO ...
Страница 204: ...204 MEMO ...
Страница 244: ...244 MEMO ...
Страница 262: ...262 MEMO ...
Страница 278: ...278 MEMO ...
Страница 290: ...290 MEMO ...