Nations Technologies Inc.
Tel
:
+86-755-86309900
:
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
420
/
631
Offset
Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
020h
OPAMP_LOCK
Reserved
OPAM
P
2L
K
OPAM
P
1L
K
Reset Value
0
0
OPAMP Control Status Register (OPAMP1_CS)
Offset address: 0x00
Reset value: 0x0000 0000
Bit field
Name
Description
31:22
Reserved
Reserved, the reset value must be maintained.
21:19
VPSSEL[2:0]
OPAMP non-inverted input secondary selection
000: VP0 (PA1);
001: VP1 (PA5);
010: VP2 (PA4);
011: VP3 (PA7);
Others: VP4(NC).
18:17
VMSSEL[1:0]
OPAMP inverted input secondary selection
00: VM0 (PA3);
01: VM1 (PC5);
10: VM2 (NC);
11: VM float (for internal PGA (no Filter ) mode and follow mode).
16
TCMEN
The Timer Controlled Mux mode is enabled.
This bit is set or cleared by the software to control the automatic switching of primary
and secondary inputs (VPSEL,VMSEL and VPSSEL,VMSSEL).
TIM1_CC6 Automatically switches between OPAMP1 and OPAMP2.
0: the automatic switchover is disabled.
1: Automatic switchover is allowed.
15
RANGE
OPAMP Operational Amplifier Power supply range.
0: low voltage range (VDDA < 2.4V);
1: high voltage range.
14
CALOUT
OPAMP Operation amplifier Calibration Output
When this signal switches, the offset during calibration mode is calibrated.
13
TSTREF
Reserved, the reset value must be maintained.