373
/
631
Bit field
Name
Description
31:15
Reserved
Reserved, the reset value must be maintained
6
JENDCA
Any injected channel end of conversion flag
This bit is set by hardware at the end of any injection channel conversion and cleared by
software.
0: Conversion is not complete;
1: Conversion is complete.
5
ENDCA
Any channel end of conversion flag
This bit is set by hardware at the end of any channel (regular or injection) conversion and
cleared by software.
0: Conversion is not complete;
1: Conversion is complete.
4
STR
Regular channel start flag
This bit is set by hardware at the start of regular channel conversion and cleared by software.
0: Regular channel conversion has not started.
1: Regular channel conversion has started.
3
JSTR
Injected channel start flag
This bit is set by hardware at the start of the injection channel conversion and cleared by
software.
0: Injection sequence channel conversion has not started.
1: Injection sequence channel conversion has started.
2
JENDC
Injected channel end of conversion
This bit is set by hardware at the end of all injection sequence channel conversions and
cleared by software
0: Conversion is not complete.
1: Conversion is complete.
1
ENDC
Conversion sequence channel end of conversion
This bit is set by hardware at the end of all regular( or injection) sequence channel
conversion and cleared by software
0: Conversion is not complete.
1: Conversion is complete.
0
AWDG
Analog watchdog flag
This bit is set by hardware and cleared by software when converted voltage values are outside
the range defined by the ADC_LTR and ADC_HTR registers
0: Analog watchdog event not occurs;
1: Analog watchdog event occurs.