background image

WARNING

Isolate supplies to both Eurotrol & heater

before removing this cover

powrmatic

 

Ltd · tel: 01460 53535 · fax: 01460 52341

www.powrmatic.co.uk · email: [email protected]

Reset

Fan Only

Heating

Override

e

Summary of Contents for Eurotrol 2

Page 1: ...RNING Isolate supplies to both Eurotrol heater before removing this cover powrmatic Ltd tel 01460 53535 fax 01460 52341 www powrmatic co uk email eurotrol powrmatic co uk Reset Fan Only Heating Override e ...

Page 2: ...2 19 Notes ...

Page 3: ...ections 7 User Keypad Programming Keypad 8 Overview Programming date and time 9 Basic and advanced operating modes Heating Fan Only modes 10 Entering the switching program 11 Advanced operation Quick mode temp offset 12 Menu options 14 Menu layout 16 Sensor wiring Connection diagrams 19 Notes ...

Page 4: ...es may be selected for different times of the day and temperatures may only be adjusted by 3 C without the use of a password The Eurotrol 2 is protected by 3 levels of password The first will allow access to the day to day operation of the ie setting times and temperatures the second allows access to parameters normally used only in the initial setting of the controller and the third is only acces...

Page 5: ...SOR REMOTE AVERAGING SENSORS IN EXTENDED MENU SET No OF SENSORS TO 2 Sensor Wiring A single remote sensor may be used in place of the standard internal sensor Two remote sensors may be used which relay an average of the two temperatures back to the Eurotrol 2 Important Sensor cable must be screened two core and a minimum of 0 6mm if solid and 7 x 0 2mm if multistrand The screen must be grounded on...

Page 6: ...r optional Remove cover and offer the sensor up to the intended mounting position and mark two fixing holes Fix sensor base plate to the wall See connection diagrams on page 16 Eurotrol 2 Remove the two screws from the terminal cover and remove Offer the unit up to the intended mounting position and mark the location of the three fixing holes using the template on the packaging box Secure the top ...

Page 7: ... or Advanced Set temperature differential Adjusts night temperature Main display 14 7 A short press of either button will place the control into that respective mode until midnight of that day Indicated by a flashing H for heating or F for fan only in the display Pressing either button for 5 secs will permanently place the control into that respective mode Indicated by a steady H for heating or F ...

Page 8: ...ew Optimum stop Set temperature differential preprogrammed to 0ºC Optimum stop will switch off the heating to save energy before the end of the program time Example If the heating program calls for the building to be heated to 20ºC but it is felt that at the end of the heating program this temperature could drop to 18ºC with no detrimental effect then the optimum stop should be set to 2ºC 20ºC 18º...

Page 9: ...r to select basic or advanced Heating Fan Only modes A short press of either button will place the control into that respective mode for the remainder of the day Indicated by a flashing H for heating or F for fan only in the display Pressing either button for 5 secs will permanently place the control into that respective mode Indicated by a steady H for heating or F for fan only in the display Fan...

Page 10: ...then the set point will have been adjusted to 22 C 20 2 22 Entering the switching program BASIC OPERATION Important As the Eurotrol 2 is an optimum start controller the program start time should be when occupancy begins and no pre heat time should be allowed for 10 11 Individual days may be programmed with up to 3 entries P1 P3 and a Monday to Friday block may also be set with a further 3 entries ...

Reviews: