Nations Technologies Inc.
Tel
:
+86-755-86309900
:
Address: Nations Tower, #109 Baoshen Road, Hi-tech Park North.
Nanshan District, Shenzhen, 518057, P.R.China
276
/
631
Prescaler (TIMx_PSC)
Offset address: 0x28
Reset value: 0x0000
Bit field
Name
Description
15:0
PSC[15:0]
Prescaler value
Counter clock f
CK_CNT
= f
CK_PSC
/ (PSC [15:0] +1).
Each time an update event occurs, the PSC value is loaded into the active prescaler register.
Auto-reload register (TIMx_AR)
Offset address: 0x2C
Reset values: 0xFFFF
Bit field
Name
Description
15:0
AR[15:0]
Auto-reload value
These bits define the value that will be loaded into the actual auto-reload register.
See Section 11.3.1 for more details.
When the TIMx_AR.AR [15:0] value is null, the counter does not work.
Capture/compare register 1 (TIMx_CCDAT1)
Offset address: 0x34
Reset value: 0x0000
Bit field
Name
Description
15:0
CCDAT1[15:0]
Capture/Compare 1 value
CC1 channel is configured as output:
CCDAT1 contains the value to be compared to the counter TIMx_CNT, signaling on the OC1
output.