background image

H3C WAC360 Series Access Controllers

Installation Guide

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
New H3C Technologies Co., Ltd. 
http://www.h3c.com.hk 
 
Document version:6W101-20170616

 

 

Summary of Contents for WAC360 Series

Page 1: ...H3C WAC360 Series Access Controllers Installation Guide New H3C Technologies Co Ltd http www h3c com hk Document version 6W101 20170616...

Page 2: ...her trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without notice Every effort has been made i...

Page 3: ...ents commands and keywords that you enter literally as shown Italic Italic text represents arguments that you replace with actual values Square brackets enclose syntax choices keywords or arguments th...

Page 4: ...rmation NOTE An alert that contains additional or supplementary information TIP An alert that provides helpful information Network topology icons Represents a generic network device such as a router s...

Page 5: ...fer from what you have on your device Obtaining documentation To access the most up to date H3C product documentation go to the H3C website at http www h3c com hk To obtain information about installat...

Page 6: ...t cables 11 Connecting the power adapter 11 Verifying the installation 12 Powering on the device 12 Troubleshooting 14 Power failure 14 No display or garbled display on the configuration terminal 14 L...

Page 7: ...ii Technical specifications 22 Interface arrangement 23 Appendix B LEDs 24 LEDs 24 Index 25...

Page 8: ...tes in the voltage range as required Use a screwdriver to fasten screws To prevent condensation perform the following tasks Unpack the device a minimum of half an hour after you move the device from a...

Page 9: ...perature humidity requirements in the equipment room Temperature Relative humidity 0 C to 40 C 32 F to 104 F 5 to 95 noncondensing Cleanliness Dust buildup on the chassis can result in electrostatic a...

Page 10: ...ling the device EMI All electromagnetic interference EMI sources from outside or inside of the switch and application system adversely affect the switch in the following ways A conduction pattern of c...

Page 11: ...ty and temperature are at acceptable levels EMI prevention Take effective measures to protect the power system from the power grid system Separate the protection ground of the device from the groundin...

Page 12: ...the chassis contact H3C Support for permission Otherwise H3C shall not be liable for any consequence Confirming installation preparations Before you install the device verify that you have read Prepa...

Page 13: ...le to the grounding system in the equipment room Do not connect it to a fire main or lightning rod No grounding cable is provided with the device Prepare a grounding cable yourself Attaching the ring...

Page 14: ...2 Use the grounding screw to attach the ring terminal of the grounding cable to the chassis 3 Connect the other end of the grounding cable to the grounding strip Make sure the grounding strip has been...

Page 15: ...le NOTE Identify the mark on the console port and make sure you are connecting to the correct port The serial ports on PCs do not support hot swapping To connect a PC to an operating device first conn...

Page 16: ...the Connect using list and click OK Figure 7 Setting the serial port used by the HyperTerminal connection 4 Set Bits per second to 9600 Data bits to 8 Parity to None Stop bits to 1 and Flow control t...

Page 17: ...Figure 8 Setting the serial port parameters 5 Select File Properties in the HyperTerminal window Figure 9 HyperTerminal window 6 On the Settings tab set the emulation to VT100 or Auto detect and click...

Page 18: ...et port on the peer device 2 After powering on the device examine the LEDs of the fixed copper Ethernet port For more information about the LED description see Appendix B LEDs Connecting the power ada...

Page 19: ...he following uses the WAC360 access controller as an example To start the device 1 Power on the device The device initializes its memory and runs BootWare The following information appears on the term...

Page 20: ...the system enters the system image file reading and self compressing process restart the device Starting to get the main application file flash main bin The main application file is self decompressing...

Page 21: ...the power system is operating correctly 2 Verify that the console cable has been connected correctly 3 Verify that the following settings are configured for the terminal Baud rate 9600 Data bits 8 Par...

Page 22: ...password when you forget the console login password 1 If password recovery capability is enabled select 6 from the BootWare menu to start the system without loading the system configuration The follow...

Page 23: ...er privilege level password is restored at a second reboot b Reboot the device and you can directly enter system view If password recovery capability is disabled start the system with the factory defa...

Page 24: ...Memory Hardware Version is Ver B CPLD Version is 002 Basic Bootrom Version is 1 02 Extend Bootrom Version is 1 02 Subslot 0 WAC360 Hardware Version is Ver B Displaying operational statistics for the d...

Page 25: ...0x6 CPU Tick High 0x5aa72673 CPU Tick Low TaskName CPU Runtime CPU Tick High CPU Tick Low VIDL 98 6 3e5ae16b TICK 0 0 44f7e49 STMR 0 0 2f5ad1d DrTC 0 0 41c0f7 MCIN 0 0 7cb61 ADJ6 0 0 3a348 IPCB 0 0 4d...

Page 26: ...splaying the CPU usage of the device Use the display cpu usage command to display the CPU usage statistics for the device H3C display cpu usage Unit CPU usage 2 in last 5 seconds 2 in last 1 minute 2...

Page 27: ...d division by zero operations by using one of the following methods Reboot The device automatically reboots to recover from the error condition Maintain The device stays in the error condition so you...

Page 28: ...figuration file for the device you must reboot the device To reboot a device use one of the following methods Reboot the device immediately at the CLI Schedule a reboot at the CLI to occur at a specif...

Page 29: ...eset button RESET Figure 14 Rear view 1 Grounding screw Technical specifications Table 9 Technical specifications Item Specification Console port One 9600 bps default to 115200 bps Gigabit Ethernet po...

Page 30: ...lb Operating temperature 0 C to 40 C 32 F to 104 F Relative humidity noncondensing 5 to 95 Interface arrangement The device provides five 100 1000 Base T autosensing Ethernet copper ports GigabitEthe...

Page 31: ...ected a serious fault Flashing red slowly The Reset button is being pressed for more than 1 second This operation resets the device Flashing red quickly The Reset button is being pressed for more than...

Page 32: ...ge level password loss 16 Displaying detailed information about the device 18 Displaying operational statistics for the device 17 Displaying the CPU usage of the device 19 Displaying the electronic la...

Reviews: