Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
196
6064h Position Actual Value
Function
Contains the current actual position (encoder position converted acc. to Feed Constant (6092) and
Gear Ratio (6091) and reference position)
In open loop mode, the source of this object can be set either to the internal, calculated value or to the
encoder with object 320A
:04
h
.
In closed loop mode, the source of this object can be set either to the internal, calculated value or to
the encoder with object 320B
:04
h
.
CAUTION
The value of this object is invalid in case the object for the encoder resolution (object 2052
) is set to
the value "0" and the encoder is selected as source.
Object description
Index
6064
h
Object Name
Position Actual Value
Object Code
VARIABLE
Data type
INTEGER32
Saveable
No
Access
Read only
PDO Mapping
TX - PDO
Admissible Values
Specified Value
00000000
h
Firmware Version
FIR-v1426
Change History
6065h Following Error Window
Function
Specifies the maximum following error symmetrically to the demanded position.
Object description
Index
6065
h
Object Name
Following Error Window
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
00000100
h
Firmware Version
FIR-v1426
Change History
Firmware Version FIR-v1504: Entry "Saveable" modified from "No" to
"yes, category: application".