![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520027.webp)
Manual PD4-C (USB)
7 Setup and commissioning
Version: 1.4.1 / 22.07.2016 / FIR-v1626
27
•
Voltage supply in accordance with the data sheet
•
Additional voltage source unit for "enable" input
Corresponding to the mode to be used:
•
For analogue mode: An additional voltage source 0 V to 10 V
•
For clock-direction mode: Clock generator
7.2.1 Clock Direction mode
Read the "Configuration" section for the motor controller if you have not yet done so
1. Switch off any connected voltage supply.
2. Set all DIP switches to the "Off" state (corresponds the base setting when delivered):
1
2
3
4
ON
3. Connect the voltage supply to connector X3 of the motor controller (see "Voltage supply
4. Connect the clock generator to connector X2 (see "Clock-direction inputs (connector X2)")
The motor must change the speed of rotation when the clock generator frequency changes.
7.2.2 Analogue mode
CAUTION
Make sure that the voltage at the analogue input does not exceed the value of 10 V.
Read the "Configuration" section on the motor controller if you have not already done so.
1. Switch off any connected voltage supply.
2. All DIP switches must - except for switch 1 - be at the "Off" state:
1
2
3
4
ON
3. Connect the voltage supply to connector X3 of the motor controller (see "Voltage supply
4. Connect the adjustable voltage source supply to connector X1 pin 2 (see "Analogue input
The motor must change the speed when the voltage is changed at the input for the analogue input.
7.2.3 Auto-Setup
To determine some parameter referring the motor and the connected controller an auto-setup is
performed.
CAUTION
Prerequisites for performing the auto setup are:
•
The motor must be load-free.
•
The motor must not be touched.
•
The motor must be able to rotate freely in any direction.