Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
121
CAN
Value = "1": A CANopen interface is available.
E-NET
Value = "1": An EtherNET interface is available.
E-CAT
Value = "1": An EtherCAT interface is available.
SPI
Value = "1": A SPI interface is available.
MRTU
Value = "1": The protocol used is Modbus RTU.
MTCP
Value = "1": The protocol used is Modbus TCP
E-IP
Value = "1": The protocol used is EtherNet/IP
™
2102h Fieldbus Module Control
Function
With this object certain field busses (physical interfaces and protocols) can get activated or
deactivated.
Object description
Index
2102
h
Object Name
Fieldbus Module Control
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: communication
Savable
yes, category: application
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00090001
h
Firmware Version
FIR-v1540
Change History
Firmware Version FIR-v1626: Entry "Saveable" modified from "yes,
category: application" to "yes, category: communication".
Description
:1
h
all physical interfaces and protocols are listed, which are able to get activated or
deactivated. These object can get switched here. The actual state of the activated field busses are punt
into 2103
h
:2
h
.
Thereby the following distribution of the bits apply: