![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 129](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520129.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
129
Data type
UNSIGNED32
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
00000000
h
Description
The subindices have the following functions:
•
01
h
specifies the maximum size of the sampler buffer in bytes.
•
02
h
contains the momentary filling level of the sampler buffer in bytes.
•
03
h
contains a numerator that is incremented with each scan.
2204h Sample Time In Ms
Function
This object contains the scan interval of the sampler in milliseconds.
Object description
Index
2204
h
Object Name
Sample Time In Ms
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
00000001
h
Firmware Version
FIR-v1426
Change History
Firmware Version FIR-v1626: Entry "Saveable" modified from "No" to
"yes, category: application".
2300h NanoJ Control
Function
Controls the execution of a user program.
Object description
Index
2300
h
Object Name
NanoJ Control
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values