![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520026.webp)
Manual PD4-C (USB)
7 Setup and commissioning
Version: 1.4.1 / 22.07.2016 / FIR-v1626
26
7 Setup and commissioning
7.1 Safety instructions
!
WARNING
Operation:
•
Never touch rotating parts of the motor while the motor is running. Otherwise there is a danger of
injury.
•
The motor shaft must be disconnected from the machine in order to prevent unpredictable
accidents. Otherwise there is a danger of injury.
•
Before starting operation with connected machine, change the settings while taking into account
the para- meters of the machine. If you start operation without taking the correct settings into
account, the machine can run out of control or cause malfunctions.
•
Before starting operation with connected machine, make sure that an emergency-stop can be
carried out at any time. Otherwise there is a danger of injury.
•
Do not touch any of the motors during operation. Otherwise the high temperatures can cause
panic reactions.
Maintenance and Inspection:
•
Do not attempt to disconnect the motor from the positioning control while the voltage is switched
on. There is a danger of electric shock and destruction of the positioning control.
•
After switching off the voltage supply wait until the back-up capacitors have discharged. There is a
danger of electric shock from the residual voltage.
•
Do not disassemble the stepper motor or the positioning control. The components are
maintenance-free and opening them will invalidate any claim under guarantee. Otherwise there is
a danger of electric shock or injury.
•
Do not attempt to change the wiring while the voltage supply is switched on. Otherwise there is a
danger of electric shock or injury.
In residential areas, this product may cause high-frequency interference and may require interference
suppression measures.
!
CAUTION
Alternating electromagnetic fields!
Alternating electromagnetic fields around current-carrying cables, especially around the supply and
motor cables, can cause interference in the motor and other devices.
•
Shield the cables. Run the shield connection on one side or both sides to a short earth.
•
Use twisted pair cables.
•
Keep power supply and motor cables as short as possible.
•
Ground the motor housing large-area to a short earth.
•
Run supply, motor and control cables separately.
7.2 General
Before starting the set up and commissioning read the chapter "Technical data and pin
configuration" and "Configuration".
The following components are required for set up and installation:
•
Motor controller PD4-C