![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520155.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
155
•
PD4-C5918M4204-KSAR2: 00004E20
h
Sub-index
04
h
Name
Velocity Loop, Integral Gain (closed Loop)
Data type
INTEGER32
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
•
: 0000001E
h
•
PD4-C5918M4204-E-01: 00000064
h
•
PD4-C6018L4204-E-01: 00000004
h
•
PD4-CB59M024035-E-01: 000001F4
h
•
PD4-C5918L4204-E-01: 00000064
h
•
PD4-C5918M4204-KSAR2: 00000064
h
Sub-index
05
h
Name
Flux Current Loop, Proportional Gain (closed Loop)
Data type
INTEGER32
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
•
: 000668A0
h
•
PD4-C5918M4204-E-01: 0007A120
h
•
PD4-C6018L4204-E-01: 000668A0
h
•
PD4-CB59M024035-E-01: 000061A8
h
•
PD4-C5918L4204-E-01: 0007A120
h
•
PD4-C5918M4204-KSAR2: 0007A120
h
Sub-index
06
h
Name
Flux Current Loop, Integral Gain (closed Loop)
Data type
INTEGER32
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
•
: 00002EE0
h
•
PD4-C5918M4204-E-01: 00001388
h
•
PD4-C6018L4204-E-01: 00002EE0
h
•
PD4-CB59M024035-E-01: 00000BB8
h
•
PD4-C5918L4204-E-01: 00001388
h
•
PD4-C5918M4204-KSAR2: 00001388
h
Sub-index
07
h
Name
Torque Current Loop, Proportional Gain (closed Loop)
Data type
INTEGER32
Access
Read/write
PDO Mapping
No
Admissible Values