12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
197
Description
If the value of the following error window is set to "FFFFFFFF"
h
, the following control is switched off.
If the difference between the actual position and the set position is so large that value of this object
is exceeded, an error will be noted in the object 1003
. The deviation must be longer than the time in
object 6066
h
.
a reaction for the following error can be set.
6066h Following Error Time Out
Function
Time in milliseconds until too large a following error leads to an error message.
Object description
Index
6066
h
Object Name
Following Error Time Out
Object Code
VARIABLE
Data type
UNSIGNED16
Saveable
yes, category: application
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
0064
h
Firmware Version
FIR-v1426
Change History
Firmware Version FIR-v1504: Entry "Saveable" modified from "No" to
"yes, category: application".
Description
If the difference between the actual position and the set position is so large that the value of object
6065
is exceeded, the bit 11 "Internal Limit Reached" in the object 6041
h
(statusword) is set. The
deviation must be longer than the time in this object.
a reaction for the following error can be set.
6067h Position Window
Function
Specifies a symmetrical range relative to the target position within which the target is considered to be
reached.
If the value of the position window is FFFFFFFF
h
, the position window control is switched off.
Object description
Index
6067
h
Object Name
Position Window
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable