8 General concepts
Version: 1.4.1 / 22.07.2016 / FIR-v1626
31
Note: If an error that cannot be corrected occurs, the motor controller changes to the "Not ready to
switch on" state and stays there. These errors includes an encoder error (e.g. due to missing shielding,
cable breakage)
8.1.2 Behavior after the "Operation enabled" state is left
Brake reactions
Different brake reactions can be programmed when leaving the "Operation enabled" state.
These include the transitions described below.
The following diagram shows an overview of the brake reactions.
Not ready to
switch on
Start
Software cannot
rectify error
Switched on
disabled
Ready to
switch on
Switched on
Operation
enabled
Quick stop
active
Fault
Fault reaction
active
Error occures
Torque
voltage switched on for controller
High-level voltage switched on
High-level power
voltage switched on for controller
High-level voltage switched on
No torque at motor
Low-level power
voltage switched on for controller
High-level voltage can be switched on
605A
h
Halt
605E
h
605A
h
605C
h
605C
h
Disable
voltage
Transfer with
break reaction
Transfer without
break reaction
Index of the object that
specifies the reaction
Quick stop active
Transition to the "Quick stop active" state (quick stop option):
In this case, the action stored in object 605A
is executed (see the following table).
Value in object 605A
h
Description
-32768 to -1
Reserved
0
Immediate stop with short-circuit braking