![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 204](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520204.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
204
Description
If this range is exceeded or undercut, an overflow occurs. Limit values for the target position can be set
in object 607D
h
("Software Position Limit") to prevent this overflow.
607Ch Home Offset
Function
Specifies the difference between the zero position of the application and the reference point of the
machine. This object is computed in the same unit used for calculation for object 607A
h
(see " User-
Object description
Index
607C
h
Object Name
Home Offset
Object Code
VARIABLE
Data type
INTEGER32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
RX - PDO
Admissible Values
Specified Value
00000000
h
Firmware Version
FIR-v1426
Change History
607Dh Software Position Limit
Function
Limit values for the target position.
Object description
Index
607D
h
Object Name
Software Position Limit
Object Code
ARRAY
Data type
INTEGER32
Saveable
yes, category: application
Firmware Version
FIR-v1426
Change History
Value description
Sub-index
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
02
h