![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520104.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
104
Description
h
greater/equal 0 and smaller than value in 2031
h
The current is reduced to the value entered in object 2037
h
. The value is in mA and used as root
mean square (RMS).
h
is between -1 and -100
The value in 2037
h
is interpreted as the percentage reduction factor relative to 2031
.
was set to 4200 mA. The value -60 in object 2037
h
will reduce the
current as root means square (RMS) up to 60 % in comparison to 2031
h
. As a result you'll get a
current reduction down to 2031
+ 100) / 100 = 1680 mA.
The value "-100" in 2037
h
as a further example will reduce the current reduction to 0 mA.
2039h Motor Currents
Function
This object contains the measured motor currents in mA.
Object description
Index
2039
h
Object Name
Motor Currents
Object Code
ARRAY
Data type
INTEGER32
Saveable
No
Firmware Version
FIR-v1426
Change History
Firmware Version FIR-v1504: Table entry "PDO Mapping" at sub-index
01 modified from "No" to "TX - PDO".
Firmware Version FIR-v1504: Table entry "PDO Mapping" at sub-index
02 modified from "No" to "TX - PDO".
Firmware Version FIR-v1504: Table entry "PDO Mapping" at sub-index
03 modified from "No" to "TX - PDO".
Firmware Version FIR-v1504: Table entry "PDO Mapping" at sub-index
04 modified from "No" to "TX - PDO".
Value description
Sub-index
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
04
h
Sub-index
01
h
Name
I_d
Data type
INTEGER32
Access
Read only