![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520098.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
98
202Ah MODBUS RTU Baudrate
Funktion
This object contains the baudrate of modbus in Bd.
Object description
Index
202A
h
Object Name
MODBUS RTU Baudrate
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: communication
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00004B00
h
Firmware Version
FIR-v1436
Change History
202Ch MODBUS RTU Stop Bits
Funktion
This object contains the number of stop-bits of modbus interface.
Object description
Index
202C
h
Object Name
MODBUS RTU Stop Bits
Object Code
VARIABLE
Data type
UNSIGNED8
Saveable
No
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
01
h
Firmware Version
FIR-v1436
Change History
Firmware Version FIR-v1540: Entry "Saveable" modified from "yes,
category: communication" to "No".
Firmware Version FIR-v1540: Table entry "Access" at sub-index 00
modified from "Read/write" to "Read only".
Description
Number of Stopbits
Value in object 202C
h
1
0
2
2