Object Code
VARIABLE
Data type
INTEGER16
Saveable
yes, category: application
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
0001
h
Firmware Version
FIR-v1426
Change History
Description
Value
Description
-32768 to 0
Reserved
1
Braking with "slow down ramp" (deceleration depending on operating mode)
2
Braking with "quick stop ramp" (deceleration depending on operating mode)
3 to 32767
Reserved
605Eh Fault Option Code
Function
The object contains the action that is to be executed when the motor needs to be brought to idling in
case of a fault.
Object description
Index
605E
h
Object Name
Fault Option Code
Object Code
VARIABLE
Data type
INTEGER16
Saveable
yes, category: application
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
0002
h
Firmware Version
FIR-v1426
Change History
Description
Value
Description
-32768 to -1
Reserved
0
Immediate stop with short-circuit braking
1
Braking with "slow down ramp" (deceleration depending on operating mode)
2
Braking with "quick stop ramp" (deceleration depending on operating mode)
3 to 32767
Reserved