![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 150](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520150.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
150
CL/OL
Switchover between open loop and closed loop
•
Value = "0": Open loop
•
Value = "1": Closed loop
VoS
Value = "1": Simulate v-control via an S ramp
Brake
Value = "1": Switch on the brake controller
CurRed (Current Reduction)
Value = "1": Current reduction activated in open loop
Torque
Only active in Profile Torque Mode
Value = "1": M-control is active, otherwise a V-control is superimposed
BLDC
Value = "1": Motor type "BLDC" (brushless DC motor)
320Ah Motor Drive Sensor Display Open Loop
Function
It can be used to change the source for objects 6044
and 6064
in open loop mode.
Object description
Index
320A
h
Object Name
Motor Drive Sensor Display Open Loop
Object Code
ARRAY
Data type
INTEGER32
Saveable
yes, category: application
Firmware Version
FIR-v1426
Change History
Value description
Sub-index
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
Read only
PDO Mapping
No
Admissible Values
Specified Value
04
h
Sub-index
01
h
Name
Commutation
Data type
INTEGER32