![NANOTEC PD4-C5918M4204-E-01 Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520151.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
151
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00000000
h
Sub-index
02
h
Name
Torque
Data type
INTEGER32
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00000000
h
Sub-index
03
h
Name
Velocity
Data type
INTEGER32
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00000001
h
Sub-index
04
h
Name
Position
Data type
INTEGER32
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00000001
h
Description
The following subindices haven a meaning:
•
01
h
: Unused
•
02
h
: Unused
•
03
h
: Changes the source of object 6044
:
•
Value = "-1": The internally calculated value is entered in object 6044
h
•
Value = "0": The value is kept at 0
•
Value = "1": The encoder value is entered in object 6044
•
04
h
: Changes the source of object 6064
:
•
Value = "-1": The internally calculated value is entered in object 6064
h
•
Value = "0": The value is kept at 0
•
Value = "1": The encoder value is entered in object 6064
320Bh Motor Drive Sensor Display Closed Loop
Function
It can be used to change the source for objects 6044
and 6064
in closed loop mode.