3-100
Attribute 2 - Individual Autodialer Setting
(Equivalent to Memory Switch 11)
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 1
The time between reception of CFR and transmission of data. (For T.4.1 error)
When CFR and data overlap due to line echo, increase the interval between CFR
and data transmission using this switch.
250 ms 500 ms 750 ms 1000 ms
Switch 7 0 0 1 1
Switch 6 0 1 0 1
5 0
4 0
Interval between DCS and TCF. (For T.2.3 error.)
When FTT is received after DCS and TCF signals due to line echo, increase the
interval between DCS and TCF signals using this switch.
75 ms 300 ms 450 ms 600 ms
Switch 5 0 0 1 1
Switch 4 0 1 0 1
3 1
2 0
1 1
0 1
Output attenuation
See table below.
Memory Switch 11…Output attenuation
Switch -15
dB
-14
dB
-13
dB
-12
dB
-11
dB
-10
dB
-9
dB
-8
dB
-7
dB
-6
dB
-5
dB
-4
dB
-3
dB
-2
dB
-1
dB
-0
dB
3
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
2
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
Attribute 3 - Individual Autodialer
Setting (Equivalent to Memory Switch 12)
Switch
Initial
Setting
Adjust Usage/Comments
7 0
Data signaling rate (DCS)
0: V.17
1: V.33
Determines communication protocol.
6 0
Disable the memory to
memory transmission
0: No
1: Yes
If the remote machine is Muratec machine and it
has capability of “directly printing”, when setting this
switch to “1” will disable the “memory to memory
transmission”.
This switch will prevent a memory overflow error at
the remote Muratec machine.
5 0
European date format on TTI
0: No
1: Yes
Assigns European date format to the transmitted
TTI.
(Example: 31 Aug. 2001)
4 1
TTI transmit
0: No
1: Yes
When set at “0”, transmission of the TTI is
disabled. (Note: Turning TTI transmission off may
violate local or federal regulations.)
3 0
ECM response time
0: 3 sec
1: 4.8 sec
The time limit to receive the response signal for the
ECM post message.
2 0
ECM error retransmit time
0: 200 ms
1: 400 ms
The time limit before the ECM error is
retransmitted.
1 0
0 0
Interval between DIS and DCS. (For T.2.1 error)
0 ms 500 ms 1000 ms 1500 ms
Switch 1 0 0 1 1
Switch 0 0 1 0 1