3-23
Machine Parameter 90
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Printer registration
adjustment (Vertical) at the
cassette.
Adjusts the start point to
print.
The plus setting increases
the top margin and the minus
setting decreases it.
Each setting changes by
0.042 mm
Switch 76543210 Settings
01111111 5.3 mm Maximum
|
|
00000011 0.13 mm
00000010 0.08 mm
00000001 0.042 mm
00000000 Initial setting
10000001 -0.042 mm
10000010 -0.08 mm
10000011 -0.13 mm
|
|
11111111 -5.3 mm Minimum
Machine Parameter 91
Switch
Initial
Setting
Adjust Usage/Comments
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Printer registration
adjustment (Vertical) at the
bypass tray.
Adjusts the start point to
print.
The plus setting increases
the top margin and the minus
setting decreases it.
Each setting changes by
0.042 mm
Switch 76543210 Settings
01111111 5.3 mm Maximum
|
|
00000011 0.13 mm
00000010 0.08 mm
00000001 0.042 mm
00000000 Initial setting
10000001 -0.042 mm
10000010 -0.08 mm
10000011 -0.13 mm
|
|
11111111 -5.3 mm Minimum