3-65
Unique Switch 21 - Reception
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 1
5 1
4 0
T1 timer adjustment
When the unit switches to fax by on-hook transfer,
the unit will seize the telephone line and attempt to
handshake.
Switch 7 5 6 4 Settings
0 0 0 0 0 s
0 0 0 1 2 s
0 0 1 0 4 s
0 0 1 1 6 s
0 1 0 0 8 s
0 1 0 1 10 s
0 1 1 0 12 s
←
Initial setting
0 1 1 1 14 s
1 0 0 0 16 s
1 0 0 1 18 s
1 0 1 0 20 s
1 0 1 1 22 s
1 1 0 0 24 s
1 1 0 1 26 s
1 1 1 0 28s
1 1 1 1 30 s
3 1
2 0
1 1
0 0
TCF check time
(in 100 ms units)
If the TCF time is such that poor image quality is the
result, lengthen the TCF check time.
Switch 3 2 1 0 Time
0 0 0 0 0 ms
0 0 0 1 100 ms
0 0 1 0 200 ms
0 0 1 1 300 ms
0 1 0 0 400 ms
0 1 0 1 500 ms
0 1 1 0 600 ms
0 1 1 1 700 ms
1 0 0 0 800 ms
1 0 0 1 900 ms
1 0 1 0 1000 ms Initial setting
1 0 1 1 1100 ms
1 1 0 0 1200 ms
1 1 0 1 1300 ms
1 1 1 0 1400 ms
1 1 1 1 1500 ms