3-43
Memory Switch 61 - Remote reception and TAD interface
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 1
4 1
Off-hook / on-hook detect
time for remote reception
Sets the time interval between the off-hook/on-hook
condition for remote reception.
Note:
The total time of this time and the time
specified in Memory switch 66 will be the actual
time.
Switch 7 6 5 4 Time
0 0 0 0 0 ms
0 0 0 1 10 ms
0 0 1 0 20 ms
0 0 1 1 30 ms Initial setting
0 1 0 0 40 ms
0 1 0 1 50 ms
0 1 1 0 60 ms
0 1 1 1 70 ms
1 0 0 0 80 ms
1 0 0 1 90 ms
1 0 1 0 100 ms
1 0 1 1 110 ms
1 1 0 0 120 ms
1 1 0 1 130 ms
1 1 1 0 140 ms
1 1 1 1 150 ms
3 0
2 1
1 0
0 0
Off-hook / on-hook detect
time
Sets the time interval between the on-hook and off-
hook(or off-hook/on-hook) condition.
Switch 3 2 1 0 Time
0 0 0 0 0 ms
0 0 0 1 100 ms
0 0 1 0 200 ms
0 0 1 1 300 ms
0 1 0 0 400 ms Initial setting
0 1 0 1 500 ms
0 1 1 0 600 ms
0 1 1 1 700 ms
1 0 0 0 800 ms
1 0 0 1 900 ms
1 0 1 0 1000 ms
1 0 1 1 1100 ms
1 1 0 0 1200 ms
1 1 0 1 1300 ms
1 1 1 0 1400 ms
1 1 1 1 1500 ms