3-115
3.13.2 Tonal Signal Test
The tonal signal test permits the unit’s output tones to be monitored.
Note:
To monitor the tones, an external monitoring device must be connected to the telephone line jack.
1. Press
MENU, *, 1, 2.
2. Press the numeric keypad 0 (zero) to select the main board.
To select the optional board number for the second phone line, press 1 (one).
Then press
ENTER
.
3. Select
“Tonal Test”
, then press
ENTER
.
4. Select the desired tonal signal using cursor key.
Refer to the following table.
No. Signal No. Signal
01
None (stop signal)
11
FSK black (all 1)
02
462 Hz tone
12
FSK White 1 : Black 1
03
1080 Hz tone
13
V27_1200_2400 picture data
04
1300 Hz tone
14
V27_1600_4800 picture data
05
1650 Hz tone
15
V27_2400_7200 picture data
06
1700 Hz tone
16
V27_2400_9600 picture data
07
1800 Hz tone
17
V17_2400_7200 picture data
08
1850 Hz tone
18
V17_2400_9600 picture data
09
2100 Hz tone
19
V17_2400_12000 picture data
10
FSK white (all 0)
20
V27_2400_14400 picture data
No. Signal No. Signal
21 – 29
V34_2400_2400 to 21600
51 – 62
V34_3200_4800 to 31200
30 – 39
V34_2800_4800 to 26400
63 – 75
V34_34290_4800 to 33600
40 – 50
V34_3000_4800 to 28800
76
Voice