3-34
Memory Switch 16 - Transmission
Switch
Initial
Setting
Adjust Usage/Comments
7 0
Not
used
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
1
Additional data on TTI
transmit
0: No
1: Yes
When set at “0”, the transmission of the additional
data (time, the number of pages, file number, etc)
is disabled.
Note:
This switch is available only when Memory
switch 12, bit 4 and/or Memory switch 13, bit 5 is
available.
2
1
Subscriber ID transmit
0: No
1: Yes
When set at “0”, the transmission of the subscriber
ID is disabled.
Note:
This switch is available only when Memory
switch 12, bit 4 and/or Memory switch 13, bit 5 is
available.
1
1
TTI (name) transmit
0: No
1: Yes
When set at “0”, the transmission of the name
which was stored in the unit is disabled.
Note:
This switch is available only when Memory
switch 12, bit 4 and/or Memory switch 13, bit 5 is
available.
0 0
Not
used
Memory Switch 17 to 19 - Transmission
Switch
Initial
Setting
Adjust Usage/Comments
7
0
Not used
6
0
Not used
5
0
Not used
4
0
Not used
3
0
Not used
2
0
Not used
1
0
Not used
0
0
Not used