3.18 Life monitor maintenance
When you replace the main control PCB, you should register the previous counter values of the life monitor.
1. Before updating the software or replacing the main control PCB, you must write down the counter values of
the life monitor.
2. To confirm the life monitor, see “3.10.1 Life Monitor,” page 3-106.
3. After you write down the counter values of the life monitor, update the software or replace the main control
PCB.
4. Then press
MENU, *, 2, 0.
Enter previous value of the drum replaced count.
5. Press
ENTER
.
Enter previous value of the total pages printed with the current drum.
6. Press
ENTER
.
Enter previous value of the toner replaced count.
7. Press
ENTER
.
Enter previous value of the toner life
8. Press
ENTER
.
Enter previous value of the fuser replaced count.