Memory Switch 65 - Remote reception and TAD interface
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
Adjusts the detect time for
the CI signal.
Increase/decrease the time specified in this switch
from the standard detect time. Determine it in bit 3
of Memory switch 65 whether increase or decrease.
Switch 7 6 5 4
Time
0 0 0 1
10 msec
0 0 1 0
20 msec
0 0 1 1
30 msec
|
|
1 1 1 1
150 msec
3 0
Adjust the detect time for
regarding as the CI signal.
0: decrease
1: increase
Increase/decrease the time specified in bit 4 to 7 of
Memory switch 65 from the standard detect time.
2 0
Not used
1 0
Not used
0 0
Beep if fax handset hanged
up
0: Yes
1: No
Determines if your fax beeps when having left the
fax’s handset hanging up after communication.
Memory Switch 66 - Remote reception and TAD interface
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Off-hook / on-hook detect
time for remote reception
Sets the time interval between the off-hook/on-
hook condition for remote reception. The total time
of this time and the time specified in 61 bit 4 to 7
will be the actual time.
Switch 7 6 5 4 3 2 1 0 Time
0 0 0 0 0 0 0 0 0 ms Initial setting
0 0 0 0 0 0 0 1 20 ms
0 0 0 0 0 0 1 0 40 ms
0 0 0 0 0 0 1 1 60 ms
0 0 0 0 0 1 0 0 80 ms
|
|
1 1 1 1 1 1 1 0 5080 ms
1 1 1 1 1 1 1 1 5100 ms