3-70
Unique Switch 30 - Modem
Switch
Initial
Setting
Adjust Usage/Comments
7 0
Factory use only
6 0
Factory use only
5 1
3429 baud symbol rate when
communicating at V.34
0: No
1: Yes
4 1
3200 baud symbol rate when
communicating at V.34
0: No
1: Yes
3 1
3000 baud symbol rate when
communicating at V.34
0: No
1: Yes
2 1
2800 baud symbol rate when
communicating at V.34
0: No
1: Yes
If the error frame occurs because of the symbol
rate is too high, setting this switch to “1” masks that
symbol rate and decreases the occurrence of error
frame.
1 0
Factory use only
0 1
2400 baud symbol rate when
communicating at V.34
0: No
1: Yes
See above (switch 5 to 2 of Memory switch 30).
Unique Switch 31 - Modem
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 1
3 0
2 1
1 0
0 0
Forced 2400 symbol rate
when probing SNR is
adverse
SNR means that Signal Noise Ratio.
If the SNR is less than the threshold you set, the
modem overrides the bandwidth evaluation
algorithm and forces the symbol rate to2400 baud.