3-94
Unique Switch 87 - Miscellaneous
Switch
Initial
Setting
Adjust Usage/Comments
7 1
Factory use only
6 0
Flash ROM polling (Host)
0: No
1: Yes
If this machine is used as host machine which is
polled for the latest software update in this
machine, turn this switch to “1”.
Refer to page 3-131 to setup the software version
to be polled.
5 0
Flash ROM polling (Client)
0: No
1: Yes
To update the software by polling from the other
F-360 that is programmed as the host machine,
turn this switch to “1”.
Refer to page 3-131 to poll for the latest software.
4 0
Factory use only
3 0
Factory use only
2 0
Factory use only
1 0
Print “year” on Activity journal
and TCR
0: No
1: Yes
0 0
Print last 25-digits of remote
number on TCR
0: No
1: Yes
Determines if printing the “
•
•
”, followed by the last
25-digit of remote number on TCR, when the
remote number exceeded the ability of its column
on TCR.
Unique Switch 88 – Miscellaneous (for OP-150 setting)
Switch
Initial
Setting
Adjust Usage/Comments
7 0
Disable the PCL feature of
OP-150
0: No
1: Yes
If this switch is set to “1”, the PCL print feature of
optional OP-150 is disabled.
6 0
Disable the TWAIN feature of
OP-150
0: No
1: Yes
If this switch is set to “1”, the TWAIN feature of
optional OP-150 is disabled.
5 0
Not used
4 0
Not used
3 0
Restriction of horizontal line
0: No
1: Yes
If memory over error caused enlarge processing
etc., change this switch to “1”.
2 0
Factory use only
1 0
Factory use only
0 0
Fixed output document on a
PC
0: Not fixed size
1: Fixed size
(See next page)
When scanning two or more documents, some
software applications cannot display the scanned
document if their size is not the same as the first
page.
Changing this switch to “1” may solve this problem.
Содержание F-360
Страница 12: ...2 1 Section2 Machine Composition 2 1 F 360 Interconnect Block Diagram...
Страница 13: ...2 2...
Страница 14: ...2 3 F 320 Interconnect Block Diagram...
Страница 254: ...6 29 13 Attach the paper tray of the 2 Bin unit...