Ds230_03a_oi_e.doc / Jun-15
Page 22 / 100
5.6.
SinCos-Splitter-Output
(only DS230 and DS240)
The DS230 respective the DS240 has a safety-related SinCos-Splitter-Output. Depending on the
selected operating mode (0, 1, 2 or 6), the integrated splitter function allows to reproduce the signal
at input terminal [X6 | SINCOS IN 1] to the female 9-pin SUB-D connector [X5
| SINCOS OUT
]. Thus the
encoder signal connected to [X6 | SINCOS IN 1] can be processed by a further target device.
The signal delay time between SinCos input and SinCos output is approximately 200 ns.
The channels SIN+ and SIN- resp. COS+ and COS- must be terminated by 120 Ohm load resistors at
the target device.
In case of errors, the DC-offset of the SinCos output is shifted in order to signalize the error
condition to the target device.
The connection to the SinCos splitter output is only safe, if the following device includes a SinCos
monitoring system and can detect the offset error.
female SUB-D Connector [X5]
The channels SIN+ and SIN- resp. COS+ and COS- must be terminated by
120 Ohm load resistors at the target device.
Содержание DS230 Series
Страница 10: ...Ds230_03a_oi_e doc Jun 15 Page 10 100 4 3 DS236 Block Diagram 4 4 DS236 Connections...
Страница 11: ...Ds230_03a_oi_e doc Jun 15 Page 11 100 4 5 DS240 Block Diagram 4 6 DS240 Connections...
Страница 12: ...Ds230_03a_oi_e doc Jun 15 Page 12 100 4 7 DS246 Block Diagram 4 8 DS246 Connections...
Страница 99: ...Ds230_03a_oi_e doc Jun 15 Page 99 100 11 1 Dimensions inclusive BG230 at front Front Rear DS230 BG230 option...